Skip to content

AEM 30-0300

Brand AEM
Model 30-0300
Output Type Differential mode (signal ground and power supply ground are different)
Sensor Type Bosch LSU 4.9
Fuse 5A

Wideband controller with display. Can be connected to 12V battery or a 12V/5A power supply.

Typical installation is a fixed installation in the exhaust pipe, a few centimeters after the manifold junction. In dynamometers, it can be used with an adapter at the exhaust pipe outlet as explained here.

IMPORTANT

Read the manufacturer's instructions and follow the recommendations for position, mounting, and fuse.

Connection to Accudyno

Connect the grounds together

Wideband controllers with differential analog output have a negative output different from the battery negative. For them to work properly with Accudyno, all grounds must be connected at a common point, as shown in the figure, since Accudyno has common mode input, not differential.

Loading SVG...
Wire/Color Function Gyra/Forza
Red Positive Power Supply (+) Battery(+)
Black Negative Power Supply (-) Battery(-)
White Analog Output (+) AIN1
Brown Analog Output (-) GND and Battery(-)

Loading SVG...
Wire/Color Function GO/PRO
Red Positive Power Supply (+) Battery(+)
Black Negative Power Supply (-) Battery(-)
White Analog Output (+) Accudyno IN+ (AFR Pin 3)
Brown Analog Output (-) Accudyno IN- (AFR Pin 2) and Battery(-)

Calibration

Voltage Lambda AFR (Gasoline)
0.5 V 0.58 8.5
4.5 V 1.23 18.0