Skip to content

AEM 30-4110

Brand AEM
Model 30-4110
Output Type Common mode (signal ground and power supply ground are common)
Sensor Type Bosch LSU 4.9
Fuse 10A

Wideband controller with display. Can be connected to 12V battery or a 12V/5A power supply.

Typical installation is a fixed installation in the exhaust pipe, a few centimeters after the manifold junction. In dynamometers, it can be used with an adapter at the exhaust pipe outlet as explained here.

IMPORTANT

Read the manufacturer's instructions and follow the recommendations for position, mounting, and fuse.

Connection to Accudyno

Join the grounds together

The ground of the wideband probe controllers must be connected together. Connect the battery ground and the signal ground as shown in the figure.

Loading SVG...
Wire/Color Function Gyra/Forza
White Analog Output (+) AIN1
Red Positive Power Supply (+) Battery(+)
Black Common Negative (-) GND and Battery(-)

Loading SVG...
Wire/Color Function GO/PRO
White Analog Output (+) Accudyno IN+ (AFR Pin 3)
Red Positive Power Supply (+) Battery(+)
Black Common Negative (-) Accudyno IN- (AFR Pin 2) and Battery(-)

Calibration

Voltage Lambda AFR (Gasoline)
0 V 0.68 10.0
5 V 1.36 20.0