Skip to content

Innovate LM-2

Brand Innovate Motorsports
Model LM-2
Output Type Differential mode (signal ground and power supply ground are different)
Sensor Type Bosch LSU 4.2
Fuse 5A

Wideband controller with display. Can be connected to 12V battery or a 12V/5A power supply.

Typical installation is a fixed installation in the exhaust pipe, a few centimeters after the manifold junction. In dynamometers, it can be used with an adapter at the exhaust pipe outlet as explained here.

IMPORTANT

Read the manufacturer's instructions and follow the recommendations for position, mounting, and fuse.

Connection to Accudyno

Connect the grounds together

Lambda probe controllers with differential analog output have a negative output different from the battery negative. For them to work properly with Accudyno, all grounds must be connected at a common point, as shown in the figure, since Accudyno has common mode input, not differential.

Loading SVG...
Wire/Color Function Gyra/Forza
Red Positive Power Supply (+) Battery(+)
Black Negative Power Supply (-) Battery(-)
Lime Green Analog Output (+) Pin 12 AIN1
Yellow Analog Output (-) Pin 5 GND and Battery(-)

Loading SVG...
Wire/Color Function GO/PRO
Red Positive Power Supply (+) Battery(+)
Black Negative Power Supply (-) Battery(-)
Lime Green Analog Output (+) Pin 12 Accudyno IN+ (AFR Pin 3)
Yellow Analog Output (-) Pin 5 Accudyno IN- (AFR Pin 2) and Battery(-)

AUXILIARY CABLE

The cable colors indicated correspond to the auxiliary cable that Innovate Motorsports sells separately. If you don't have it, you should use the pin number in the auxiliary connector as a reference. A connector numbering diagram is provided.

Innovate LM-2 Connector

Calibration

Voltage Lambda AFR (Gasoline)
0 V 0.5 7.35
5 V 1.52 22.39